This interface consists of two partitions. The first partition (NIP 1) has interface export type 1 (export mid-surface only), format type 0 (dummy), sonsists of elements 1-15, the tag of the surface mesh is 1 (used to match carat and Foam interface meshes) and no border definition is necessary.
 
This interface consists of two partitions. The first partition (NIP 1) has interface export type 1 (export mid-surface only), format type 0 (dummy), sonsists of elements 1-15, the tag of the surface mesh is 1 (used to match carat and Foam interface meshes) and no border definition is necessary.
 
The second partition (NIP 2) has interface export type 3 (export top- and bottom surface and side mesh), format type 0 (dummy), consists of elements 20-30, the tag of the three surface meshes is 1 for the top mesh, 1 for the bottom mesh and 2 for the side mesh (used to match carat and Foam interface meshes). The side mesh is defined by defining nodes, which are part of the border.
 
The second partition (NIP 2) has interface export type 3 (export top- and bottom surface and side mesh), format type 0 (dummy), consists of elements 20-30, the tag of the three surface meshes is 1 for the top mesh, 1 for the bottom mesh and 2 for the side mesh (used to match carat and Foam interface meshes). The side mesh is defined by defining nodes, which are part of the border.
 +
 +
Hint: More details on the interface definition can be found in the diploma thesis of Rupert Fisch.
  
 
=== Analysis Definition ===
 
=== Analysis Definition ===
  
 +
Defining a coupled analysis, contains of two part:
  
 +
* Defining a Analysis of type FSI as master analysis.
 +
* Defining a sub-analysis for the specific structure field behavior (static or dynamic).
  
 +
The defintion of the master analysis:
 
<pre>
 
<pre>
 
PC-ANALYSIS 1: FSI
 
PC-ANALYSIS 1: FSI
Line 64: Line 70:
 
</pre>
 
</pre>
  
 +
The sub-analysis is given by Analysis 2. The method is given as black-box (standard). Additionally, the output and the interface have to be defined.
  
A partitioned approach is used for simulating FSI problems. This means, that for each specific task of the coupled computation a specific program is used. The software envrionment in our case consists of three programms:
+
The sub-analysis block is the same as in a standard Carat++-analysis. Possible analysis types are static linear and static nonlinear and dynamic linear and nonlinear (all available time integration algorithms).  
* the FE-code Carat++ for the solution of the structural subproblem,
+
* the FV-code OpenFOAM for the solution of the fluid subproblem,
+
* the coupling code CoMA, responsible for everything else: Simulation control, data transfer, communication, coupling algorithms, ...
+
 
+
A grafical representation fo this setup is given in the following figure:
+
 
+
 
+
 
+
To do a FSI-analysis all three programs have to be installed. Only a Linux-system can be used, because OpenFOAM is only available for Linux and cluster systems for HPC typically only run under Linux OS. The specific information on installation and problem setup of the three programs is given on the bottom of this page.  After setup of the problem, the coupled computation is started by running all three programms at the same time, using MPI (Message Passing Interface):
+
 
+
<pre>
+
mpiexec -n 1 pathToCarat/carat20.exe caratInputfile : -n 1 pathToCoMA CoMA.exe comaInputfiled : -n 2 OpenFOAM.exe -case pathToFoamCase -parallel
+
</pre>
+
 
+
This command will start one carat process, one CoMA process and two OpenFOAM processes, so OpenFOAM runs in parallel.
+
  
== Single Programs in Detail ==
+
* Hint 1: The specification of an end time in a dynamic analysis is necessary in the input block, but is overriden in the coupled analysis by CoMA.
 +
* Hint 2: The loads from the fluid are just added to the loads specified in the carat++-input file. So it is possible to add e.g. self weight to the structure model.

Latest revision as of 11:01, 23 February 2011


Contents

Structure Field Solver Carat++

Carat++ is used to simulate the structure field within an FSI-analysis. Two specific aspects have to be mentioned: compilation and problem setup. All other aspects are handled in the other parts of this wiki.


Compilation

Carat++ has to installed under Linux operating system, because FSI-jobs only run under Linux. The difference with a standard installation is, that additional code parts are compiled used for communication between Carat++ and CoMA. This communication is based on MPI.

The changes are made within the file "makefile.in". To activate the additional code parts, the flag -DFSI has to added to the compiler directives:

CDIR = ... -DFSI

To use the now included MPI commands, the compiler needs to know, where to find the MPI installation. If OpenFOAM is already installed (highly recommended!), the MPI distribution shipped with OpenFOAM should be used. This is done by adding:

LIBS = ... -IpathToMPI/include

to the Include-command.

The installation of the Trilinos solver library is not necessary for running FSI-jobs, if the built-in Carat++ solver is used.

Problem Setup

The problem setup is based on a typical Carat++-Inputfile used for a single-field analysis.

To be specific for a coupled analysis, two steps have to made:

  • The coupled interface hast to be defined. This is the geometric representation of the coupled surface between fluid and structure field.
  • A FSI-analysis is chosen, which links to an basi analysis type, e.g. a static or dynamic analysis.


Interface Definition

The interface is the geometric definition of the physical surface between fluid and structure field. It is based on the already exisiting Finite element model. Note the following:

  • Not all elements of the model have to be part of the interface. E.g. Shell and Membrane elements should be part of the model, because the surface type gives large influence from surrounding flow, but truss elements are not part, because wind influence on a truss may be neglected.
  • Not all element types are suitable for usage within the interface. Currently only shell and membrane elements are supported.
  • An export type has to be defined. Shell and membrane elements are defined by their mid-surface. It depends on the flow and the element thickness, if the mid-surface is a proper definition of the interface. If a very thin membrane element has flow influence only from one side, the mid-surface maybe a proper definition of the interface geometry. If a very thick shell is placed in a surrounding fluid (flow on top and bottom), neglecting the thickness may lead to large errors in the correct physical representation of the problem. Currently, three export types are available: (1) Use the mid-surface of the elements as the interface. (2) Do a blow-up of the mid-surface based on the thickness and a director on the surface to define a 3d representation of the model with a top and bottom surface. (3) Using approach (2) leads to wholes on the side parts of the interface. Close the whole by additional surface elements.

The interface contains different partitions, at least one. Every partition has a unique element type and a unique type of element treatment. A typical interface defintion in Carat++ looks like:

EL-IF 1
 NIP 1 1 0 (1-15)  MSHTAG=1 BORDER=;
 NIP 2 3 0 (20-30)  MSHTAG=1,1,2 BORDER=31,62;

This interface consists of two partitions. The first partition (NIP 1) has interface export type 1 (export mid-surface only), format type 0 (dummy), sonsists of elements 1-15, the tag of the surface mesh is 1 (used to match carat and Foam interface meshes) and no border definition is necessary. The second partition (NIP 2) has interface export type 3 (export top- and bottom surface and side mesh), format type 0 (dummy), consists of elements 20-30, the tag of the three surface meshes is 1 for the top mesh, 1 for the bottom mesh and 2 for the side mesh (used to match carat and Foam interface meshes). The side mesh is defined by defining nodes, which are part of the border.

Hint: More details on the interface definition can be found in the diploma thesis of Rupert Fisch.

Analysis Definition

Defining a coupled analysis, contains of two part:

  • Defining a Analysis of type FSI as master analysis.
  • Defining a sub-analysis for the specific structure field behavior (static or dynamic).

The defintion of the master analysis:

PC-ANALYSIS 1: FSI
  ANALYSIS = PC-ANALYSIS 2
  METHOD   = BLACKBOX   !BLACKBOX, SUBSPACE_LP, SUBSPACE_FD
  OUTPUT   = PC-OUT 1
  INTERFACE = EL-IF 1

The sub-analysis is given by Analysis 2. The method is given as black-box (standard). Additionally, the output and the interface have to be defined.

The sub-analysis block is the same as in a standard Carat++-analysis. Possible analysis types are static linear and static nonlinear and dynamic linear and nonlinear (all available time integration algorithms).

  • Hint 1: The specification of an end time in a dynamic analysis is necessary in the input block, but is overriden in the coupled analysis by CoMA.
  • Hint 2: The loads from the fluid are just added to the loads specified in the carat++-input file. So it is possible to add e.g. self weight to the structure model.