Users:General FEM Analysis/Analyses Reference/Static Linear
(→Parameter Description) |
|||
Line 4: | Line 4: | ||
== General Description == | == General Description == | ||
− | The linear static analysis is applied to analyze displacements, strains or stresses of structures. This analysis is valid for linear static mechanical problems without any nonlinearity (geometrically nonlinear, contact, material nonlinear, ...). Static nonlinear problems | + | The linear static analysis is applied to analyze displacements, strains or stresses of structures. This analysis is valid for linear static mechanical problems without any nonlinearity (geometrically nonlinear, contact, material nonlinear, ...). Static nonlinear problems can be solved by the [[Users:General FEM Analysis/Analyses Reference/Static Nonlinear|static nonlinear analysis]] whereas transient problems are solved by [[Users:General FEM Analysis/Analyses_Reference/Dynamic_Analysis|dynamic analysis methods]]. |
The static linear analysis formulates structural equilibrium on the initial configuration without consideration of deformations. Hence, it is only valid for problems showing small displacements. | The static linear analysis formulates structural equilibrium on the initial configuration without consideration of deformations. Hence, it is only valid for problems showing small displacements. | ||
Line 10: | Line 10: | ||
=== Structure of Equation System === | === Structure of Equation System === | ||
− | The linear static analysis solves the problem '''K'''*'''U'''='''F''', with the linear stiffness matrix '''K''', the unknown displacement fields '''U''' and the right hand side vectors '''F'''. This system of equations is solved for the unknown displacements by a linear solver. In general, linear solvers may be separated in iterative and direct solvers. Direct solvers transform the stiffness matrix '''K''' into an upper diagonal matrix. The displacement field follow by a back substitution with the respective right hand side vector. | + | The linear static analysis solves the problem |
+ | |||
+ | '''K'''*'''U'''='''F''', | ||
+ | |||
+ | with the linear stiffness matrix '''K''', the unknown displacement fields '''U''' and the right hand side vectors '''F'''. This system of equations is solved for the unknown displacements by a linear solver. In general, linear solvers may be separated in iterative and direct solvers. Direct solvers transform the stiffness matrix '''K''' into an upper diagonal matrix. The displacement field follow by a back substitution with the respective right hand side vector. This back substitution requires only small numerical effort which makes direct solvers very attractive if a couple of displacement fields have to be computed. | ||
Line 50: | Line 54: | ||
</pre> | </pre> | ||
− | |||
− | + | == Examples == | |
− | + | === A Full Example: Bending of a cantilever discretized with shell elements === | |
+ | The following example describes a simple cantilever problem discretized by [[Users:General FEM Analysis/Elements Reference/Shell8|SHELL8]]-elements. The respective input file can be found at | ||
+ | * ..\examples\benchmark_examples\elements\shell8_quad_lin_canti_I\shell8_canti_2x20_elem_load.dat | ||
The problem computes three computation cases (dead load, snow load and pressure load). The [[Users:General FEM Analysis/BCs Reference|boundary conditions]] are visualized by the figure below. | The problem computes three computation cases (dead load, snow load and pressure load). The [[Users:General FEM Analysis/BCs Reference|boundary conditions]] are visualized by the figure below. | ||
Line 73: | Line 78: | ||
|} | |} | ||
It can be seen that the stresses show maximum values at the support region of the cantilever. At the tip they are nearly zero. In contrast to analytical results the stresses are not exactly zero in numerical models. The reason is the stress computation at the Gauss points. These points are situated inside the elements and not exactly at the tip of the cantilever. | It can be seen that the stresses show maximum values at the support region of the cantilever. At the tip they are nearly zero. In contrast to analytical results the stresses are not exactly zero in numerical models. The reason is the stress computation at the Gauss points. These points are situated inside the elements and not exactly at the tip of the cantilever. | ||
+ | |||
+ | |||
+ | === Benchmark examples === | ||
+ | * Cantilever under different surface loads, discretized [[Users:General FEM Analysis/Elements Reference/Shell8|SHELL8]]-elements ..\examples\benchmark_examples\elements\shell8_quad_lin_canti_I\shell8_canti_2x20_elem_load.dat | ||
+ | * Truss under tension discretized by [[Users:General FEM Analysis/Elements Reference/SolidHexa1|SOLIDHEXA1]]-elements: ..\examples\benchmark_examples\analyses\stalin_cantilever_hexa_I\cbm_biegebalken.txt |
Revision as of 08:27, 7 December 2016
Contents |
General Description
The linear static analysis is applied to analyze displacements, strains or stresses of structures. This analysis is valid for linear static mechanical problems without any nonlinearity (geometrically nonlinear, contact, material nonlinear, ...). Static nonlinear problems can be solved by the static nonlinear analysis whereas transient problems are solved by dynamic analysis methods.
The static linear analysis formulates structural equilibrium on the initial configuration without consideration of deformations. Hence, it is only valid for problems showing small displacements.
Structure of Equation System
The linear static analysis solves the problem
K*U=F,
with the linear stiffness matrix K, the unknown displacement fields U and the right hand side vectors F. This system of equations is solved for the unknown displacements by a linear solver. In general, linear solvers may be separated in iterative and direct solvers. Direct solvers transform the stiffness matrix K into an upper diagonal matrix. The displacement field follow by a back substitution with the respective right hand side vector. This back substitution requires only small numerical effort which makes direct solvers very attractive if a couple of displacement fields have to be computed.
Input Parameters
Parameter Description
Compulsory Parameters | ||
Parameter | Values, Default(*) | Description |
---|---|---|
SOLVER | PC-SOLVER int | Linking to a linear solver (direct or iterative) |
OUTPUT | PC-OUT int | Linking to output objects (specifies the type of output format, e.g. GiD) |
COMPCASE | LD-COM int | Linking to computation case objects which specify the boundary conditions (loading and supports) |
DOMAIN | EL-DOMAIN int | Linking to the domain the analysis should work on |
Example of a Complete Input Block
PC-ANALYSIS 1: STA_GEO_LIN SOLVER = PC-SOLVER 5 OUTPUT = PC-OUT 1 COMPCASE = LD-COM 1,2,3 DOMAIN = EL-DOMAIN 1
Examples
A Full Example: Bending of a cantilever discretized with shell elements
The following example describes a simple cantilever problem discretized by SHELL8-elements. The respective input file can be found at
- ..\examples\benchmark_examples\elements\shell8_quad_lin_canti_I\shell8_canti_2x20_elem_load.dat
The problem computes three computation cases (dead load, snow load and pressure load). The boundary conditions are visualized by the figure below.
The basic goal of each linear static analysis is the computation of the displacement field. For load case 1 this result is depicted in the figure below, whereas the deformation in z-direction is additionally visualized by the color plot.
It can be seen that the support region does not show any deformation whereas the tip region deforms by a value of 8.76.
Often the stress distribution is visualized by color plots. Shell structures require the specification of the layer on which the stresses are computed. The picture below shows the first principle stress on the top of the cantilever.
It can be seen that the stresses show maximum values at the support region of the cantilever. At the tip they are nearly zero. In contrast to analytical results the stresses are not exactly zero in numerical models. The reason is the stress computation at the Gauss points. These points are situated inside the elements and not exactly at the tip of the cantilever.
Benchmark examples
- Cantilever under different surface loads, discretized SHELL8-elements ..\examples\benchmark_examples\elements\shell8_quad_lin_canti_I\shell8_canti_2x20_elem_load.dat
- Truss under tension discretized by SOLIDHEXA1-elements: ..\examples\benchmark_examples\analyses\stalin_cantilever_hexa_I\cbm_biegebalken.txt